Strength band
high along the fibre; nodes and glue lines dominate engineered boards
Bamboo · A fast grass culm sold as timber — scaffolding, flooring and a glue story that decides the indoor air.
Darker cells mean a higher score for this topic on that metric.
LessMore
Last reviewed Sources & creditsMedia creditsMethodology
Declared reaction class in this atlas: untreated D-class typical; treated products vary. Assemblies still need resistance tests.
Thermal mark 40/100 versus the atlas. Conductivity note: ~0.1–0.2 W/m·K across the wall.
~0.6–0.8 g/cm³ culm
Origin story: ancient scaffolding; industrial strand board late 20th c. (East and South Asia).
Circularity mark 86/100 — editorial, route-specific.
chars; does not melt
heat 28 · fire 32
Numbers below are bands used by working engineers, not live quotes. Tensile note: high along the fibre; nodes and glue lines dominate engineered boards.
Fire performance in this atlas is editorial. Real projects need the assembly report.
high along the fibre; nodes and glue lines dominate engineered boards
Modulus follows chemistry and orientation — not the marketing nickname.
Crack growth, not peak stress, retires most real parts.
Cyclic and time-dependent damage dominate certificates issued on static coupons.
Indentation, drape or compressive class — whichever the trade actually measures.
~0.1–0.2 W/m·K across the wall — Bamboo is not a substitute for a dedicated λ layer.
Melting / softening / decomposition band: chars; does not melt.
Joints and clearances must follow the expansion class of Bamboo, not of steel-by-habit.
Density ~0.6–0.8 g/cm³ culm sets how fast a section changes temperature.
Foams, VIPs and moist batts drift; quote aged values.
Bamboo is generally a dielectric or semiconductor film, not building wire.
Fillers and moisture change resistivity more than brochures admit.
IACS, volume resistivity or dielectric strength — pick the quantity the job uses.
Typical declared class: untreated D-class typical; treated products vary. This is not a universal passport.
Euroclass is reaction. EI/R ratings are assemblies — boards, coats, cavities.
Bamboo can burn or drip; do not treat it as A1 without a system test.
CO, HCN, HF or fibres — the species depend on chemistry. Name the test (ISO 5659, EN 45545, NFPA 1971).
If a salesperson quotes a single “safety score”, ask which standard, which thickness, which year.
Frozen silicate liquid — windows, bottles, fibres and a Euroclass A1 skin that still shatters and melts in fire.
Overall 58 💎Crystalline oxides and carbides for heat, wear and electronics — not the mug on the desk.
Overall 64 🏗️The hydraulic ceramic of cities — cement, water, rock and usually steel, with a fire story better than exposed steel.
Overall 57 🌲Anisotropic cellulose composite grown as trees — carpentry, mass timber and a combustible story that codes still manage.
Overall 57